If the performance of the machine is poor or excessive sparking is observed through the
ventilation slots, the carbon brushes must be replaced. Remove the two covers of the brush
housing (23) with a screwdriver. Remove the two worn brushes. Insert the new brushes (29),
replace the covers and screw them into position. The new brushes may cause sparging until
they have taken on the shape of the motor. Repeat the procedure at the other side.
CAUTION: The brushes must always be replaced in pairs.
CAUTION: Always disconnect the machine from the power supply before removing any
electrical covers.
7 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
7.1 Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
8 TECHNICAL DATA
9 NOISE
Noise values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
10 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).